Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
An. sist. sanit. Navar ; 46(2): e1049, May-Ago. 2023. tab
Artigo em Inglês | IBECS | ID: ibc-227748

RESUMO

Background: Mouthwashes are increasingly being used worldwide. However, these preparations are known to have a negative impact on composite resin dental restorations. In this study, we aim to evaluate the effect of mouthwashes on the microhardness of such restorations. Methods: Thirty specimens of Tetric NCeram composite were prepared. Each composite specimen was cured for 40 seconds and kept in saline solution for 24 hours at 37 °C. Baseline microhardness of each specimen was recorded using an Innovatest Vickers Micro Hardness Tester. Composite specimens were randomly placed in 20 mL of the selected mouthwashes (Colgate® Plax, Listerine® Teeth & Gum Defence, and Closeup® Antibacterial Mouthwash Cool Breeze) and stored in an incubator for 24 hours at 37 °C. Next, microhardness values were rechecked. pH measurements were recorded for each type of mouthwash using a digital pH meter. Results: Due to the acidic nature of Colgate® and Listerine®, the microhardness of the restorations decreased with these mouthwashes; Listerine® caused the greatest decrease in microhardness and had the lowest pH reading (4.34). For Closeup®, with a neutral pH (7.02), no negative effect on microhardness was found; on the contrary, due to the presence of zinc in this latter mouthwash, an increase of the microhardness was found. Conclusions: We confirm the negative effect of acidic mouthwashes on the microhardness of composite dental restorations.(AU)


Fundamento: El uso de colutorios bucales está aumentando a nivel mundial. Sin embargo, es conocido que afectan negativamente a las reparaciones dentales de composite, por lo que el objetivo de este estudio es evaluar el efecto de los colutorios bucales sobre la microdureza de estas reparaciones. Métodos: Se prepararon treinta muestras de composite Tetric NCeram. Cada muestra compuesta se curó durante 40 segundos y se mantuvo en solución salina durante 24 horas a 37 °C. La microdureza inicial de cada muestra se registró utilizando un probador de microdureza Innovatest Vickers. Las muestras se sumergieron aleatoriamente en 20 mL de los colutorios bucales seleccionados (Colgate® Plax, Listerine® Teeth & Gum Defence y Closeup® Antibacterial Mouthwash Cool Breeze) y se incubaron a 37 °C durante 24 horas. A continuación, se volvieron a comprobar los valores de microdureza. El pH de cada colutorio bucal empleado se midió con un pHmetro digital. Resultados: Debido a la naturaleza ácida de Colgate® y Listerine®, la microdureza de las muestras de composite sumergidas en estos colutorios disminuyó; Listerine® causó la mayor disminución de microdureza y mostró el pH más bajo (4,34). Closeup®, con pH neutro (7,02), no mostró ningún efecto negativo sobre la microdureza; por el contrario, su contenido en zinc aumentó la microdureza de las muestras. Conclusiones: Los colutorios bucales ácidos mostraron un efecto negativo sobre la microdureza de las restauraciones dentales de composite.(AU)


Assuntos
Masculino , Feminino , Estética Dentária , Antissépticos Bucais , Saúde Bucal , Reparação de Restauração Dentária , Concentração de Íons de Hidrogênio
2.
Natal; s.n; 20 jul. 2023. 46 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-1532134

RESUMO

Objetivo: Avaliar a profundidade de polimerização em diferentes espessuras da resina composta Tetric® N-Flow Bulk Fill com adição de xilitol em diferentes concentrações. Metodologia: A resina Tetric® N-Flow Bulk Fill foi misturada às concentrações do xilitol (0% [Controle], 2,5% e 5% g/g) por espatulação manual durante 1 min em uma câmara escura. Amostras cilíndricas foram confeccionadas em moldes de polimetilmetacrilato de 5 mm de diâmetro x 1 mm, 2 mm, 3 mm e 4 mm de espessura nas concentrações de xilitol propostas totalizando 12 grupos (n=3), fotoativadas por 10 s e armazenadas a 37º C por 24 h. Os espécimes foram submetidos ao teste de microdureza Vickers, sendo a profundidade de polimerização obtida por meio da razão base/topo. Foram utilizados testes não paramétricos de Kruskal Wallis para comparação das diferentes espessuras na mesma concentração e das diferentes concentrações na mesma espessura (p<0,05) através do software BioEstat 5.3. Resultados: Não houve diferença estatisticamente significativa entre as diferentes espessuras na mesma concentração, bem como entre as diferentes concentrações na mesma espessura (p=1,000). Todos os espécimes apresentaram profundidade de polimerização adequada (razão de dureza ≥80%), com exceção das amostras com 4 mm de espessura contendo 2,5 e 5% de xilitol, que apresentaram razão de dureza média de 79% e 74%, respectivamente. Conclusão: Nas condições deste estudo, pode-se concluir que a adição de xilitol a uma resina bulk fill fluida pode afetar a profundidade de polimerização em 4 mm (AU).


Objective: To evaluate the depth of cure at different thicknesses of the Tetric® NFlow Bulk Fill composite resin with the addition of xylitol at different concentrations. Materials and Methods: The Tetric™ N-Flow Bulk Fill resin was mixed with xylitol concentrations (0% [Control], 2.5%, and 5% g/g) by manual spatulation for 1 minute in a portable darkroom. Cylindrical samples were prepared in polymethyl methacrylate molds with diameters of 5 mm and thicknesses of 1 mm, 2 mm, 3 mm, and 4 mm at the proposed xylitol concentrations, totaling 12 groups (n=3), photoactivated for 10 seconds, and stored at 37°C for 24 hours. The specimens were subjected to Vickers microhardness testing, and the depth of cure was obtained by calculating the base/top ratio. Non-parametric Kruskal-Wallis tests were used to compare different thicknesses at the same concentration and different concentrations at the same thickness (p<0,05) using BioEstat 5.3 software. Results: There was no statistically significant difference between different thicknesses at the same concentration, as well as between different concentrations at the same thickness (p=1,000). All specimens exhibited adequate depth of cure (hardness ratio ≥80%), except for the samples with 4 mm thickness containing 2.5% and 5% xylitol, which showed average hardness ratios of 79% and 74%, respectively. Conclusion: Under the conditions of this study, it can be concluded that the addition of xylitol to a fluid bulk fill resin can affect the depth of cure at 4 mm (AU).


Assuntos
Teste de Materiais , Estatísticas não Paramétricas
3.
Odovtos (En linea) ; 25(1)abr. 2023.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1422197

RESUMO

This study evaluated selected structural and physical properties, such as degree of conversion (DC), Vickers hardness (VHN), and compression strength (CS), of three new dual-cure bulk-fill resin-based composites (RBCs; ACTIVA, HyperFIL, and Fill-Up) and compared them to those of a conventional RBC (Filtek Z250) at three clinically relevant depths. Samples (n=180) were prepared in three depths (2,4, and 6mm). Fourier-transform infrared spectroscopy (FTIR) analysis and VHN and CS tests were performed. The DC value was calculated by considering the relative change in the aliphatic C=C peaks. The fractured surfaces of representative samples were characterized using scanning electron microscopy (SEM). Data were statistically evaluated using two-way analysis of variance and post hoc Bonferroni tests (p<0.05). According to the VHN results, Filtek Z250 showed the highest bottom/top hardness ratio (97.94±1.01) at 2mm thickness and ACTIVA showed the lowest bottom/top hardness ratio (43.48±5.64) at 6mm thickness (p<0.001). According to the FTIR results, the DC decreased with increasing thickness in all materials (p<0.05). Filtek Z250 showed the highest (301±12.4 MPa) and ACTIVA exhibited the lowest (232±17.2 MPa) CS values at 2mm thickness (p<0.05). The lowest CS values were obtained for ACTIVA, and the highest values were obtained for Filtek Z250 for samples with thicknesses of 4 and 6mm, respectively (p<0.05). The structural features of restorative composites, such as the resin chemistry and filler type and content, and the operational parameters (i.e., material thickness and curing conditions) strongly affect crosslinking reactions and thus the DC, VHN, and CS values.


Este estudio evaluó propiedades físicas y estructurales, como el grado de conversión (DC), la dureza Vickers (VHN) y la resistencia a la compresión (CS), de tres nuevos compósitos a base de resina de curado dual tipo bulk (RBC; ACTIVA , HyperFIL y Fill-Up) y los comparó con los de una resina compuesta convencional (Filtek Z250) en tres profundidades clínicamente relevantes. Se prepararon muestras (n=180) en tres profundidades (2,4 y 6mm). Se realizaron análisis de espectroscopia infrarroja por transformada de Fourier (FTIR) y pruebas VHN y CS. El valor de DC se calculó considerando el cambio relativo en los picos alifáticos C=C. Las superficies fracturadas de muestras representativas se caracterizaron mediante microscopía electrónica de barrido (MEB). Los datos se evaluaron estadísticamente mediante análisis de varianza de dos vías y pruebas post hoc de Bonferroni (p<0,05). De acuerdo con los resultados de VHN, Filtek Z250 mostró la relación de dureza inferior/superior más alta (97,94±1,01) con un espesor de 2mm y ACTIVA mostró la relación de dureza inferior/superior más baja (43,48±5,64) con un espesor de 6mm (p<0,001). De acuerdo con los resultados de FTIR, la DC disminuyó al aumentar el espesor en todos los materiales (p<0,05). Filtek Z250 mostró los valores de CS más altos (301±12,4 MPa) y ACTIVA los más bajos (232±17,2 MPa) a 2mm de espesor (p<0,05). Los valores más bajos de CS se obtuvieron para ACTIVA y los valores más altos para Filtek Z250 para muestras con espesores de 4 y 6mm, respectivamente (p<0,05). Las características estructurales de las resinas compuestas de restauración, como la química; además del tipo y contenido del relleno, y los parámetros operativos (es decir, el espesor del material y las condiciones de curado) afectan en gran medida las reacciones de interacción química y, por lo tanto, los valores de DC, VHN y CS.


Assuntos
Microscopia Eletrônica de Varredura , Resinas Compostas/análise , Força Compressiva
4.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406163

RESUMO

Abstract This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: suprananohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.


Resumen Este estudio evalúa el efecto del modo y tiempo de fotocurado sobre las propiedades mecánicas de los nanocompuestos. Se investigaron dos resinas nanocompuestas: supra-nanohíbrida (Estelite Posterior Quick; EP) y nanohíbrida (Solare X; SX). Se polimerizaron con unidades de fotopolimerización de diodos emisores de luz (LED LCU, Valo) de la siguiente manera: modo estándar durante 20s (ST20), modo de alta potencia durante 12s (HP12), modo de alta potencia durante 20s (HP20) , modo extra power durante 6s (XP6) y modo extra power durante 20s (XP20). Para la microdureza Vickers (HV), se fabricaron especímenes en forma de disco (n=10). Para el ensayo de flexión de tres puntos, se fabricaron probetas en forma de barra (n=10). Se calcularon la resistencia a la flexión y el módulo de resistencia. Las superficies fracturadas se observaron mediante microscopía electrónica de barrido. Los datos se analizaron con ANOVA varianza de dos vías y pruebas de Bonferroni (p<0,05). En las superficies superior e inferior de la resina nanocompuesta EP, ST20 y HP12 revelaron un HV estadísticamente mayor que con XP6. Además, HP20 y XP20 tenían un HV estadísticamente más alto que HP12 y XP6. Para la resina nanocompuesta SX, HP20 tenía un HV estadísticamente más alto que HP12. Para EP y SX, no hubo diferencias significativas en la resistencia a la flexión y el módulo de resistencia con respecto al modo y tiempo de fotocurado. Además, SX demostró propiedades mecánicas inferiores que EP. La microscopía electrónica de barrido indicó que ambos nanocompuestos son similares en la superficie. Sin embargo, SX exhibió fracturas en capas y más formaciones de grietas que EP. Diferentes modos y tiempos de fotocurado podrían influir en la microdureza de los nanocompuestos.


Assuntos
Nanocompostos , Cura Luminosa de Adesivos Dentários , Turquia
5.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1421848

RESUMO

To try to reduce the deleterious effects of tooth whitening, bioactive materials have been used. Forty enamel/dentin blocks were stained on dark tea and randomly assigned into four groups (n=10): control group (unbleached), HP35 % (35 % hydrogen peroxide), BG45S5 (Bioglass 45S5® incorporated into HP35 %), and BIO (Biosilicate® incorporated into HP35 %). Colorimetric analysis and microhardness evaluation was performed at baseline, 24 hours and 7 days after the final whitening session. Two-way ANOVA for repeated measures and Bonferroni test was used at a significance level of 5 %. All the coordinates (ΔL*, Δa*, Δb*, ΔE00 and WID) showed a difference between the control group and the experimental ones (p0.05), which suggest a color stability over a week. In contrast, after 7 days, the WID showed that control and PH35 % were different than the other groups (p 0.05). The microhardness did not change over time (p>0.05), except for 35 % HP. In conclusion Bioglass 45S5® and Biosilicate® prevented enamel damage without negatively affect the whitening efficacy.


Para intentar reducir los efectos nocivos del aclaramiento dental, se han usado materiales bioactivos. Cuarenta bloques de esmalte/dentina se tiñeron con té oscuro y se asignaron al azar en cuatro grupos (n=10): grupo de control (sin blanquear), HP35% (peróxido de hidrógeno al 35 %), BG45S5 (Bioglass 45S5® incorporado en HP35%) y BIO (Biosilicato® incorporado a HP35%). El análisis colorimétrico y la evaluación de la microdureza se realizaron al inicio del estudio, 24 horas y 7 días después de la última sesión de blanqueamiento. Se utilizó ANOVA de dos vías para medidas repetidas y la prueba de Bonferroni a un nivel de significancia del 5 %. Todas las coordenadas (ΔL*, Δa*, Δb*, ΔE00 y WID) mostraron diferencia entre el grupo control y el experimental (p0.05), lo que sugiere una estabilidad del color durante una semana. En cambio, a los 7 días, el WID mostró que el control y el PH35 % eran diferentes a los demás grupos (p 0.05). La microdureza no cambió con el tiempo (p>0.05), excepto para 35 % HP. En conclusión Bioglass 45S5® y Biosilicate® previnieron el daño del esmalte sin afectar negativamente la eficacia del blanqueamiento.

6.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1405321

RESUMO

ABSTRACT: Bioactive materials have shown positive results in reducing the deleterious effects of tooth whitening. However, their effects on whitening efficacy is still uncertain. Therefore, the aim of this study was to evaluate the effects of F- 18 bioactive glass incorporation into a bleaching gel on color and microhardness of enamel after tooth whitening. Thirty bovine enamel-stained specimens were randomly divided into three groups (n=10) according to the whitening protocol: control group (unbleached), HP35 % (35 % hydrogen peroxide) and F-18 (F-18 bioactive glass incorporated into HP35 %). pH, color change and microhardness analyzes were performed at baseline, 24 hours and 7 days after tooth whitening. Color evaluation showed that experimental groups were different than control group for all coordinates (p 0.05). No differences in enamel microhardness were found among the groups within the same evaluation time (p > 0.118). Regarding the intragroup comparisons, no differences were observed for control and F-18 groups (p > 0.129). It was concluded that F-18 bioactive glass incorporation did not affect the whitening efficacy and the enamel microhardness.


RESUMEN: Los materiales bioactivos han mostrado resultados positivos en la reducción de efectos nocivos del aclaramiento dental. Sin embargo, sus efectos sobre la eficacia del aclaramiento aún son inciertos. Por lo tanto, el objetivo de este estudio fue evaluar los efectos de la incorporación de vidrio bioactivo F-18 en un gel aclarador sobre el color y la microdureza del esmalte después del aclariamiento dental. Treinta especímenes bovinos teñidos con esmalte se dividieron aleatoriamente en tres grupos (n=10) de acuerdo con el protocolo de aclaramiento: grupo control (sin aclaramiento), HP35 % (peróxido de hidrógeno al 35 %) y F-18 (vidrio bioactivo F-18 incorporado en HP35 %). Se realizaron análisis de pH, cambio de color y microdureza al inicio del estudio, 24 horas y 7 días después del aclaramiento dental. La evaluación del color mostró que los grupos experimentales eran diferentes al grupo de control en todas las coordenadas (p 0,05). No se encontraron diferencias en la microdureza del esmalte entre los grupos dentro del mismo periodo de evaluación (p > 0,118). En cuanto a las comparaciones intragrupos, no se observaron diferencias para los grupos control y F-18 (p > 0,129). Se concluyó que la incorporación de vidrio bioactivo F-18 no afectó la eficacia de aclaramiento ni la microdureza del esmalte.

7.
Odovtos (En línea) ; 24(2)ago. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386596

RESUMO

Abstract Surface changes of restorative materials after bleaching have clinical importance in terms of the durability and survival of restorations. This study aimed to evaluate the effect of home bleaching on the surface roughness, microhardness, and surface analysis of four different types of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) materials. Specimens were prepared from composite resin (Brilliant Crios: BC), resin nanoceramic (Lava Ultimate: LU), polymerinfiltrated ceramic-network (Vita Enamic: VE), and zirconia-reinforced lithium silicate glass-ceramic (Vita Suprinity: VS) CAD/CAM materials. Specimens were polished using 800, 1000, 1200, and 2000 grit SiC papers. Each restorative material was randomly divided into two groups; control and bleaching (n=10). The 16% carbamide peroxide bleaching agent (Whiteness Perfect 16%, FGM) was applied to the specimens for 4 h/ day for 14 days. Surface roughness values (Ra) were obtained using a profilometer, and microhardness values (VHN) were obtained using a Vickers microhardness test. Surface analysis of specimens was evaluated by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). Data were analyzed Two-way ANOVA and Fishers Least Significant Difference (LSD) test (p<0.05). After bleaching, the surface roughness of BC (p<0.001) and VE (p<0.032) significantly increased. Bleaching did not significantly affect the microhardness of CAD/CAM materials. SEM evaluation showed material-dependent surface damages after bleaching procedures. The effect of 16% carbamide peroxide home bleaching agent on surface roughness and microhardness of chairside CAD/CAM materials is material-dependent. Before bleaching, restorative materials should be protected by applying a protective barrier and contact with the bleaching agent should be minimized. Also, after bleaching, the restoration surface should be carefully inspected, and re-polishing might be beneficial.


Resumen Los cambios en la superficie de los materiales de restauración tras el blanqueamiento tienen importancia clínica en cuanto a la durabilidad y supervivencia de las restauraciones. Este estudio tenía como objetivo evaluar el efecto del blanqueamiento en casa sobre la rugosidad de la superficie, la microdureza y el análisis de la superficie de cuatro tipos diferentes de materiales de diseño asistido por computadora y fabricación asistida por computadora (CAD/CAM). Se prepararon especímenes de materiales CAD/CAM de resina compuesta (Brilliant Crios: BC), de nanocerámica de resina (Lava Ultimate: LU), de cerámica en red infiltrada por polímeros (Vita Enamic: VE) y de cerámica de vidrio de silicato de litio reforzada con circonio (Vita Suprinity: VS). Las muestras se pulieron con papeles de SiC de grano 800, 1000, 1200 y 2000. Cada material de restauración se dividió aleatoriamente en dos grupos: control y blanqueo (n=10). El agente blanqueador de peróxido de carbamida al 16% (Whiteness Perfect 16%, FGM) se aplicó a las muestras durante 4 h/día durante 14 días. Los valores de rugosidad de la superficie (Ra) se obtuvieron utilizando un perfilómetro, y los valores de microdureza (VHN) se obtuvieron utilizando una prueba de microdureza Vickers. El análisis de la superficie de las muestras se evaluó mediante microscopía electrónica de barrido (SEM) y espectroscopia de rayos X de energía dispersiva (EDX). Los datos se analizaron mediante ANOVA de dos vías y la prueba de diferencia mínima significativa (LSD) de Fisher (p<0,05). Tras el blanqueamiento, la rugosidad de la superficie del CB (p<0,001) y del VE (p<0,032) aumentó significativamente. El blanqueamiento no afectó significativamente a la microdureza de los materiales CAD/CAM. La evaluación SEM mostró daños superficiales dependientes del material después de los procedimientos de blanqueo. El efecto del agente blanqueador casero de peróxido de carbamida al 16% sobre la rugosidad de la superficie y la microdureza de los materiales CAD/CAM en el sillón depende del material. Antes del blanqueamiento, los materiales de restauración deben protegerse aplicando una barrera protectora y debe minimizarse el contacto con el agente blanqueador. Además, después del blanqueamiento, la superficie de la restauración debe inspeccionarse cuidadosamente y puede ser beneficioso volver a pulirla.


Assuntos
Clareamento Dental/métodos , Desenho Assistido por Computador , Peróxido de Carbamida/efeitos adversos
8.
Odovtos (En línea) ; 24(1)abr. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386582

RESUMO

Abstract The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. In this study, three bulk-fill composites- SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. When comparing the baseline and the 24- hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.


Resumen El objetivo fue investigar el efecto del precalentamiento de tres resinas Bulk-fill, una resina compuesta convencional sobre la microdureza Vickers y la profundidad de curado de estas resinas. Se utilizaron tres composites Bulk-Fill-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), y una resina compuesta convencional G-ænial POSTERIOR (GP) como grupo de control. Las muestras se obtuvieron a temperatura ambiente (24°C) y a 55°C en modo T2 después de haber sido colocadas en un dispositivo de calentamiento durante 10 minutos. Se dividieron en ocho grupos (n=10) según el tipo de material y el proceso de calentamiento que se utilizó (precalentado y no calentado). Se probaron con un medidor de microdureza Vickers (VHN) en las superficies inferior y superior. Las primeras mediciones se obtuvieron en la línea de base; la segunda se realizó después de que las muestras se almacenaran en agua destilada a 37°C durante 24 horas. La profundidad de curado se calculó utilizando una relación de dureza inferior/ superior de las mediciones. El análisis estadístico se realizó utilizando el SPSS V23 y las pruebas de Shapiro-Wilk. Por último, se utilizó la prueba de Duncan para las comparaciones múltiples (p<0,05). VHN aumentó tras el procedimiento de precalentamiento en las resina Bulk-Fill, disminuyó en los GP. No hubo diferencias entre los valores de VHN de referencia y de 24 horas en SDR y GP. Después de 24 horas, mientras que el VHN de EST aumentó, el VHN de AFX disminuyó. No hubo diferencias entre los ratios de dureza de las muestras de AFX y EST (p<0,001) y los ratios de dureza fueron mayores que los de GP y SDR. Al comparar los valores de referencia y los de 24 horas, el VHN dependió del tipo de materiales. Se obtuvo una profundidad de curado suficiente en todos los grupos con un grosor de 2mm.


Assuntos
Resinas Compostas/análise , Aquecedores
9.
Braz. dent. sci ; 25(2): 1-11, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1367332

RESUMO

Objective: To comparatively evaluate the effect of resin infiltration, bleaching and bleaching followed by resin infiltration on the surface roughness and microhardness of human enamel with induced white spot lesions (WSLs) and their resistance to acidic challenge. Material and Methods: Sixty human specimens were randomly divided into three groups (n=20) according to the treatment modality applied; group I Icon® resin infiltration, group II bleaching and group III bleaching followed by Icon® resin infiltration. For each treatment modality, 10 specimens were tested for surface roughness and another 10 for microhardness. WSLs were artificially induced in all specimens and after treatment, all specimens were subjected to acidic challenge. Surface roughness was measured by the tapping mode of the atomic force microscope (AFM) and microhardness was measured by digital Vickers hardness tester at baseline, after induction of WSLs, after treatment and after acidic challenge. Results: Groups I and III showed significant reduction in surface roughness after treatment, while group II showed significant increase. Groups I and III showed significant increase in the microhardness after treatment, while group II showed insignificant increase. The three tested groups showed significant increase in surface roughness values and significant reduction in microhardness after acidic challenge. Conclusion: Resin infiltration and bleaching followed by resin infiltration reduced the surface roughness and enhanced the microhardness of the WSLs. The three treatment modalities failed to resist acidic challenge resulting in increasing surface roughness and reducing microhardness. (AU)


Objetivo: Avaliar comparativamente o efeito do infiltrante resinoso, clareamento e clareamento seguido de infiltração resinosa sobre a rugosidade e microdureza superficial do esmalte humano com lesões de manchas brancas induzidas (WSLs) e sua resistência ao desafio erosivo. Material e Métodos: Sessenta espécimes humanos foram divididos aleatoriamente em três grupos (n = 20) de acordo com a modalidade de tratamento aplicada; grupo I infiltrante resinoso Icon®, grupo II clareamento e grupo III clareamento seguido de infiltração resinosa Icon®. Para cada modalidade de tratamento, 10 corpos-de-prova foram testados para rugosidade superficial e outros 10 para microdureza. WSLs foram artificialmente induzidos em todas as amostras e, após o tratamento, todas as amostras foram submetidas ao desafio erosivo. A rugosidade de superfície foi medida por microscopia de força atômica em modo de contato intermitente (AFM) e a microdureza Vickers foi medida inicialmente, após a indução de WSLs, após o tratamento e após o desafio ácido. Resultados: Os grupos I e III apresentaram redução significativa da rugosidade superficial após o tratamento, enquanto o grupo II apresentou aumento significativo. Os grupos I e III apresentaram aumento significativo na microdureza após o tratamento, enquanto o grupo II apresentou aumento insignificante. Os três grupos testados mostraram aumento significativo nos valores de rugosidade superficial e redução significativa na microdureza após o desafio erosivo. Conclusão: O infiltrante resinoso e o clareamento seguido de infiltração resinosa reduziram a rugosidade de superfície e aumentaram a microdureza dos WSLs. As três modalidades de tratamento falharam em resistir ao desafio erosivo, resultando em aumento da rugosidade de superfície e redução da microdureza.(AU)


Assuntos
Humanos , Clareamento Dental , Cárie Dentária , Esmalte Dentário , Infiltração Dentária
10.
Odovtos (En línea) ; 23(2)ago. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386539

RESUMO

ABSTRACT: The purpose of this study was to evaluate and compare the effect of carbonated beverage on the surface microhardness of two acrylic materials used to fabricate temporary restorations. The study was experimental in vitro. Forty blocks of acrylic resins used in provisional restorations were made, 20 from Alike® (GC AMERICA INC., Lot 1712161) and 20 from Acryptemp® (Zhermack S.P.A., Lot 302334). After that, the blocks were immersed in distilled water for 24 hours. After this time, the initial surface microhardness was measured. Then the 20 samples of the experimental group were immersed in a carbonated drink (coca cola - soda) for 12 minutes per day, for 5 days. Finally, the final surface microhardness was measured using the Vickers microdurometer. Measures of central tendency and dispersion were used, and the Student's t test and ANOVA were performed. A mean surface microhardness of 8.8 and 7.2HV was found for the PMMA resin group (Initial and final respectively), and 9.5 and 8HV for the bisacrylate group. Statistically significant differences were found when comparing the beginning and end of each group and when comparing the two materials. The acrylic resin of polymethylmethacrylate (Alike® GC AMERICA INC.) Presented higher surface microhardness compared to the bis acrylic resin (Acrytemp® Zhermack S.P.A), after being exposed to a carbonated drink.


RESUMEN: El propósito de este estudio fue evaluar y comparar el efecto de la bebida carbonatada en la microdureza superficial de dos materiales acrílicos utilizados para confeccionar restauraciones provisionales. El estudio fue experimental in vitro. Se confeccionaron 40 bloques de resinas acrílicas utilizadas en provisorios, 20 de Alike® (GC AMERICA INC., Lote 1712161) y 20 de Acryptemp® (Zhermack S.P.A., Lote 302334). Posterior a ello, se sumergió los bloques en agua destilada por 24 horas. Pasado este tiempo se procedió a medir la microdureza superficial inicial. Luego las 20 muestras del grupo experimental se sumergieron en una bebida carbonatada (coca cola-gaseosa) durante 12 minutos por día, durante 5 días. Por último se midió la microdureza superficial final mediante el microdurómetro de Vickers. Se utilizaron medidas de tendencia central, dispersión y se realizaron la prueba t de Student y ANOVA. Se encontró una microdureza superficial media de 8,8 y 7,2HV para el grupo de resina PMMA (Inicial y final respectivamente), y 9,5 y 8HV para el grupo de bisacrilato. Se halló diferencias estadísticamente significativas al comparar el inicio y final de cada grupo y al comparar los dos materiales. La resina acrílica de polimetilmetacrilato (Alike® GC AMERICA INC.) presentó mayor microdureza superficial en comparación con la resina bis acrílica (Acrytemp® Zhermack S.P.A), después de ser expuestas a una bebida carbonatada.


Assuntos
Resinas Acrílicas/análise , Bebidas Gaseificadas/efeitos adversos , Peru , Dureza
11.
Odovtos (En línea) ; 23(2)ago. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386541

RESUMO

ABSTRACT: Objective: The aim of this study was to evaluate and compare the effects of the superficial application of two different modeling resins on the surface microhardness and discoloration of composite resins. Material and Methods: The present study used two different composites and modeling resins. The composites were placed in plastic molds. Subsequently, the modeling resins were applied on the surface of the two composite groups. The microhardness and color pertaining to all the groups were evaluated. The current study used the One-Way ANOVA and Kruskal Wallis tests, in order to perform the statistical evaluation (p<0.05). Results: The present study compared the microhardness pertaining to the groups and the highest microhardness values were observed in the Estelite Asteria group (none), whereas the lowest values were observed in the GC Essentia group (Ultradent). Moreover, the current study evaluated the color stability and the greatest discoloration was observed in the control group of the GC Essentia group, whereas the least discoloration was observed in the Estelite Asteria group that included the samples prepared using Ultradent Wetting Resin. Conclusions: The results of the present study demonstrated that the use of modeling resins, which facilitate the placement of composite resins, reduced the microhardness and discoloration of composite resins. The aforementioned effect can be attributed to the variations in the structure of the filling. However, further studies are warranted to support and verify the results of the current study.


RESUMEN: Objetivo: El objetivo del presente estudio fue evaluar y comparar los efectos de la aplicación superficial de dos resinas humectantes sobre la microdureza superficial y la decoloración de las resinas compuestas. Material y métodos: El presente estudio utilizó dos resinas humectantes y resinas de modelado diferentes. Las resinas compuestas se colocaron en moldes de plástico. Posteriormente, se aplicaron las resinas humectantes sobre la superficie de los dos grupos. Se evaluó la microdureza y el color de todos los grupos. El presente estudio utilizó las pruebas One-Way ANOVA y Kruskal Wallis, para realizar la evaluación estadística (p<0.05). Resultados: Los valores más altos de microdureza se observaron en el grupo Estelite Asteria, mientras que los menores valores se observaron en el grupo GC Essentia (Ultradent). La mayor decoloración se observó en el grupo control o el grupo GC Essentia, mientras que la menor decoloración se observó en el grupo Estelite Asteria con Ultradent Wetting Resin. Conclusiones: Los resultados del presente estudio demostraron que el uso de resinas humectantes, que facilitan la colocación de resinas compuestas, redujo la microdureza y decoloración de las resinas compuestas. El efecto mencionado anteriormente se puede atribuir a las variaciones en la estructura del relleno. Sin embargo, se necesitan más estudios para respaldar y verificar los resultados del presente estudio.


Assuntos
Resinas Compostas/análise , Dureza , Testes de Dureza , Descoloração de Dente , Turquia
12.
J. res. dent ; 9(2): 5-9, may-aug2021.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1358582

RESUMO

Objetivo: realizar um ensaio in vitro de microdureza em diferentes materiais restauradores. Métodos: Para cada material restaurador (FUJI IX - Cimento de Ionômero de Vidro; Tetric - resina composta convencional; Beautifil II; resina composta bioativa) foram confeccionadas 10 restaurações em dentes incisivos bovinos, cavitados por uma ponta diamantada 2092 KG Sonrensen, seguindo as recomendações de cada fabricante. O ensaio de microdureza foi realizado em diferentes profundidades (superfície, 0.4mm, 1.0mm, 2.0mm, 3.0mm e 4.0mm) e em dois momentos, imediatamente e 24h após a fotoativação. Os dados foram analisados pelo teste de análise de variância (ANOVA) e teste Tukey. Resultados: As médias de microdureza diminuíram significativamente com o aumento da profundidade, com valores mais baixos no primeiro momento avaliado. A resina composta bioativa apresentou as maiores médias de microdureza. Conclusão: os materiais testados apresentaram diminuição gradual da microdureza com o aumento da profundidade, sendo mais acentuada em profundidades acima de 2.0mm. Em todos os materiais restauradores, as médias de microdureza mais altas foram registradas 24 horas após a fotoativação. A resina composta bioativa apresentou os melhores resultados nas diferentes profundidades avaliadas.

13.
Rev. Asoc. Odontol. Argent ; 109(2): 76-80, ago. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1348357

RESUMO

esumen Objetivo: Comparar la microdureza de dos materiales endodónticos a base de silicato de calcio: MTA Densell Endo Sealer y TotalFill BC Sealer. Materiales y métodos: Se evaluó la microdureza de los selladores MTA Densell Endo Sealer (Grupo 1, n=5) y To- talFill BC Sealer (Grupo 2, n=5) contenidos en cilindros de dentina de vacuno a los 14 días posteriores a su fraguado. La medición se realizó a temperatura ambiente mediante la prue- ba de indentación Vickers. Se realizaron cinco indentaciones por probeta con una carga de 100 g durante 10 s cada una. Las mediciones se convirtieron a valores de dureza Vickers (HV) y los promedios de los valores HV de cada grupo se compararon por medio de la prueba t de Student con un nivel de significación de P <0,05. Resultados: A los 14 días, luego del fraguado, la mi- crodureza de MTA Densell Endo Sealer fue significativamen- te mayor (P=0,001) que la de TotalFill BC Sealer. Conclusiones: Los resultados sugieren que a causa de su dureza la remoción de MTA Densell Endo Sealer puede resultar dificultosa cuando está indicado un retratamiento (AU)


Aim: To compare the microhardness of two silicate-based endodontic materials: MTA Densell Endo Sealer and Total Fill BC Sealer. Materials and methods: Samples of MTA Densell Endo Sealer (Group 1, n=5) and Total Fill BC Sealer (Group 2, n=5) contained into cow dentine cylinders were subjected to the Vickers Microhardness Indentation test at room temper- ature and 14 days after setting. Five indentations per sample were performed under a load of 100 g for 10 s. The indenta- tion measurements were converted into hardness values (HV). Mean HV values of each group were compared using the Stu- dent t test at a significance level of P <0,05. Results: 14 days after setting, the microhardness of MTA Densell Endo Sealer was significantly greater (P=0,001) than that of Total Fill BC Sealer. Conclusions: The results of this study suggest that due to its hardness the removal of MTA Densell Endo Sealer could be difficult to perform when a root canal retreatment is indicated (AU)


Assuntos
Materiais Restauradores do Canal Radicular , Cimento de Silicato , Testes de Dureza , Teste de Materiais
14.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385745

RESUMO

ABSTRACT: The glass ionomer cements (GICs) is a generic name given to a group of materials widely used in clinical dentistry which if used after the specified expiration date, material properties may be affected. to evaluate the Vick ers microhardness, surface morphology and the energy dispersive X-ray microanalysis (EDX), of GICs with different expiration dates that were stored at room temperature. specimens of highly viscous glass ionomer cement (HVGIC) (Ketac Cem and Ketac Molar) and resin-modified glass ionomer cement (RMGIC) (Vitrebond) with different expiration dates (current, close to their expiration and expired) were prepared for Vickers microhardness test and scanning electronic microscopy (SEM) with EDX, measuring 5 mm in diameter and 2 mm length, per the manufacturer's instructions, in standard cylindrical teflon molds. For the comparison of obtained values, the ANOVA test was used, while Tukey test was used for the multiple comparisons. In all the GICs used, the microhardness decreased as the expiration date approached, finding a significant statistical differen ce (P<0.05) in Ketac Molar and Vitrebond. SEM sample analysis revealed similar cohesive cracks in all tested materials. The EDX analysis revealed the presence of the elements F, Al and Si in all GICs and Ca only in Ketac Molar and Ketac Cem. The elements were found in a higher atomic percentage in the GICs with an current date and in a lower percentage in those with an expired date. HVGIC and RMGIC with an expiration date finish and that were stored at room temperature, suffer significant physical and chemical changes, which could put doubts its clinical effectiveness.


RESUMEN: El cemento de ionómero de vidrio (CIV) es un nombre genérico que se le da a un grupo de materiales ampliamente utilizados en odontología clínica que si se usan después de la fecha de vencimiento especificada, las propiedades del material pueden verse afectadas. evaluar la microdureza Vickers, la morfología superficial y el microanálisis de energía dispersa de rayos X (EDX), de CIV con diferentes fechas de caducidad almacenados a temperatura ambiente. Muestras de cemento de ionómero de vidrio de alta viscosidad (CIVAV) (Ketac Cem y Ketac Molar) y cemento de ionómero de vidrio modificado con resina (CIVMR) (Vitrebond) con diferentes fechas de vencimiento (vigente, próximo a su vencimiento y vencido) de 5 x 2 mm, fueron preparadas para microscopía electrónica de barrido (MEB) con EDX y microdureza Vickers, según las instrucciones del fabricante, en moldes de teflón cilíndricos estándar. Para la comparación de los valores obtenidos se utilizó la prueba ANOVA, mientras que para las comparaciones múltiples se utilizó la prueba de Tukey. En todos los CIV utilizados, la microdureza disminuyó a medida que se acercaba la fecha de vencimiento, encontrándose una diferencia estadística significativa (P <0.05) en Ketac Molar y Vitrebond. El análisis de la muestra en MEB reveló grietas cohesivas similares en todos los materiales probados. El análisis EDX reveló la presencia de los elementos F, Al y Si en todos los GIC y Ca solo en Ketac Molar y Ketac Cem. Los elementos se encontraron en mayor porcentaje atómico en los GIC con fecha vigente y en menor porcentaje en aquellos con una fecha vencida. Los CIVAV y CIVMR con fecha de caducidad vencida y que fueron alma- cenados a temperatura ambiente, sufrieron cambios físicos y químicos importantes, lo que podría poner en duda su efectividad clínica.

15.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1385772

RESUMO

RESUMEN: Los instrumentos rotatorios utilizados en el tratamiento de conductos dentales necesitan cumplir con ciertas características físicas que le confieran un uso correcto, adecuado y seguro para su uso clínico. En el mercado comercial existen una serie de instrumentos importados que dejan en duda la autenticidad de estos debido a sus bajos costos. En este estudio evaluamos física, química y morfológicamente dos kits de instrumentos rotatorios Protaper universal (Dentsply) mediante análisis de MEB, EDX, microdureza y EDS. Uno de los kits (grupo 1) se adquirió directamente de la casa comercial y otro kit importado que a simple vista no parecía cumplir con los estándares de calidad de un correcto empaquetado (grupo 2). En el análisis de MEB se observaron características morfológicas muy diferentes entre ambos kits, el grupo 2 presentó diversas irregularidades en la superficie de las limas, sin embargo, en el EDS no se encontró diferencia alguna. En cuanto al análisis de microdureza se observó una estadística estadísticamente significativa y en el EDS se observaron mayores picos de intensidad en cuanto a la aleación de Ni-Ti en el grupo 2. Estos resultados sugieren que existen instrumentos rotatorios importados que a pesar de su bajo costo pueden presentar ciertas características muy similares a los kits auténticos, sin embargo, física y químicamente pueden resultar en un riesgo para su uso clínico debido a la diferencia entre estos.


ABSTRACT: Rotatory files are instruments used in the treatment of dental canals roots. These instruments need to comply with certain physical characteristics for a correct, adequate and safe use for clinical use. In the commercial market there are a series of imported instruments that cast doubt on their authenticity due to their low costs. In this study we physically, chemically and morphologically evaluated two Protaper universal rotary instrument kits (Dentsply) using SEM, EDX, microhardness and EDS analysis. One of the kits (group 1) was purchased directly from the commercial house and another imported kit that a simple view did not seem to meet the quality standards of a correct packaging (group 2). In the SEM analysis, very different morphological characteristics were observed between both kits, group 2 presented various irregularities on the surface of the files, however, no difference was found in the EDS. Regarding the microhardness analysis, a statistically significant statistic was observed and in the EDS, higher intensity peaks were observed in terms of the Ni-Ti alloy in group 2. These results suggest that there are imported rotary instruments that despite their low cost can present characteristics very similar to authentic kits, however, physically and chemically they can result in a risk for their clinical use due to the difference between them.

16.
Odontol. Clín.-Cient ; 20(2): 52-57, abr.-maio 2021. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1369004

RESUMO

As soluções de irrigação são essenciais como auxiliares na limpeza e desinfecção do sistema de canais radiculares (SCR). Entretanto, essas substâncias químicas podem gerar alterações na composição da dentina. Assim, o presente estudo teve como objetivo avaliar, por meio de uma revisão integrativa, os efeitos do hipoclorito de sódio (NaOCl) a 1%; 2,5%; 3%; 5%; 5,25%; 6% e 17%; digluconato de clorexidina (CHX) a 2% e EDTA 2,5%; 5%; 15% e 17% sobre a microdureza da dentina do canal radicular após sua utilização como solução irrigadora. Foi realizada uma revisão integrativa nas bases de dados: PubMed, Cochrane e Lilacs, utilizando-se os seguintes descritores em inglês: "irrigating solutions"; "chelaling agentes"; "dentin microhardness"; "EDTA"; "sodium hypochlorite"; "chlorhexidine gluconate". Foi utilizado o conector "and" associando dentin microhardness aos outros descritores. Critérios de inclusão: Artigos científicos na área da odontologia, escritos em inglês e português que aborda o tema "As soluções de hipoclorito de sódio (NaOCl), digluconato de clorexidina (CHX) e EDTA influenciam na microdureza da dentina radicular?''. Critérios de exclusão: artigos repetidos em mais de uma base de dados, livros, teses de doutorado, dissertações de mestrado, resumos e trabalhos publicados em congresso. Fortes evidências indicam que o hipoclorito de sódio, digluconato de clorexidina e EDTA influenciam na microdureza da dentina radicular, quando utilizadas como solução irrigadora durante o tratamento endodôntico... (AU)


Irrigation solutions are essential as an aid in cleaning and disinfecting the root canal system (SCR). However, these chemicals can cause changes in the composition of dentin. Thus, the present study aimed to evaluate, through an integrative review, the effects of 1% sodium hypochlorite (NaOCl); 2.5%; 3%; 5%; 5.25%; 6% and 17%; 2% chlorhexidine digluconate (CHX) and 2.5% EDTA; 5%; 15% and 17% on the microhardness of root canal dentin after its use as an irrigating solution. An integrative review was carried out in the databases: PubMed, Cochrane and Lilacs, using the following descriptors in English: "irrigating solutions"; "chelaling agents"; "dentin microhardness"; "EDTA"; "sodium hypochlorite"; "chlorhexidine gluconate". The "and" connector was used, associating dentin microhardness with other descriptors. Inclusion criteria: Scientific articles in the field of dentistry, written in English and Portuguese that address the topic "Do solutions of sodium hypochlorite (NaOCl), chlorhexidine gluconate (CHX) and EDTA influence the microhardness of root dentin?". Exclusion criteria: articles repeated in more than one database, books, doctoral theses, master's dissertations, abstracts and papers published in congress. Strong evidence indicates that sodium hypochlorite, chlorhexidine gluconate and EDTA influence the microhardness of root dentin when used as an irrigating solution during endodontic treatment... (AU)


Assuntos
Humanos , Irrigantes do Canal Radicular , Tratamento do Canal Radicular , Hipoclorito de Sódio , Clorexidina , Ácido Edético , Cavidade Pulpar , Dentina
17.
Biosci. j. (Online) ; 36(6): 2287-2296, 01-11-2020. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1148387

RESUMO

The aim of this study was to evaluate the effectiveness of grape seed extract (GSE)-based intracanal dressings against Enterococcus faecalis (E. faecalis) and its influence on dentin microhardness and bond strength of the filling material. The root canals of 126 human teeth were distributed into three test groups: antimicrobial activity (60 teeth), dentin microhardness (30 teeth) and bond strength (36 teeth). In all three groups, specimens were subdivided into six groups, according to intracanal dressing protocols: G1 ­ distilled water (DW); G2 ­ 2% chlorhexidine gel (CHX); G3 ­ calcium hydroxide (Ca[OH]2)+DW; G4 ­ GSE+DW; G5 ­ Ca(OH)2+CHX; G6 ­ GSE+CHX. The counting of colony-forming units (CFUs), the Vickers microhardness tester and the push-out test were performed to evaluate the antimicrobial activity, dentin microhardness and bond strength, respectively. Specific statistical analysis was performed for each evaluation (α=5%). The greatest bacterial reduction was observed in G5 (Ca[OH]2+CHX) and G6 (GSE+CHX) (p<0.05). There was no statistically significant difference among groups in the dentin microhardness evaluation (p<0.05). The highest bond strength in the immediate evaluation was observed in G4 (GSE+DW) and G6 (GSE+CHX), whereas the highest bond strength after 12 months of storage was observed in G2 (CHX), G3 (Ca[OH]2+DW), G4 (GSE+DW), and G6 (GSE+CHX) (p<0.05). After the storage period, bond strength was increased in G2 (CHX) and G3 (Ca[OH]2+DW), and remained unchanged in G4 (GSE+DW) and G6 (GSE+CHX) (p<0.05). GSE-based intracanal dressings have antimicrobial potential against E. faecalis, have no influence in dentin microhardness and preserve the high bond strength of filling materials for root dentin over time.


O objetivo deste estudo foi avaliar a eficácia de medicamentos intracanal à base de extrato de semente de uva (GSE) contra Enterococcus faecalis (E. faecalis) e sua influência na microdureza da dentina e na resistência de união do material de obturação. Os canais radiculares de 126 dentes humanos foram distribuídos em três grupos de teste: atividade antimicrobiana (60 dentes), microdureza da dentina (30 dentes) e resistência adesiva (36 dentes). Nos três grupos, as amostras foram subdivididas em seis grupos, de acordo com os protocolos de curativos intracanal: G1 ­ água destilada (DW); G2 ­ gel de clorexidina a 2% (CHX); G3 ­ hidróxido de cálcio (Ca[OH]2) +DW; G4 ­ GSE+DW; G5 ­ Ca(OH)2+CHX; G6 ­ GSE+CHX. A contagem de unidades formadoras de colônias (UFCs), o testador de microdureza Vickers e o teste push-out foram realizados para avaliar a atividade antimicrobiana, a microdureza da dentina e a resistência adesiva, respectivamente. Análise estatística específica foi realizada para cada avaliação (α=5%). A maior redução bacteriana foi observada no G5 (Ca[OH]2+CHX) e G6 (GSE+CHX) (p<0,05). Não houve diferença estatisticamente significativa entre os grupos na avaliação da microdureza da dentina (p<0,05). A maior resistência adesiva na avaliação imediata foi observada no G4 (GSE+DW) e G6 (GSE+CHX), enquanto a maior resistência adesiva após 12 meses de armazenamento foi observada no G2 (CHX), G3 (Ca[OH]2+DW), G4 (GSE+DW) e G6 (GSE+CHX) (p<0,05). Após o período de armazenamento, a resistência de união aumentou no G2 (CHX) e G3 (Ca[OH]2+DW), permanecendo inalterada no G4 (GSE+DW) e G6 (GSE+CHX) (p<0,05). Os medicamentos intracanal à base de GSE têm potencial antimicrobiano contra E. faecalis, não influenciam na microdureza da dentina e preservam a alta resistência adesiva dos materiais de obturação da dentina radicular ao longo do tempo.


Assuntos
Dentina , Extrato de Sementes de Uva , Anti-Infecciosos
18.
Biosci. j. (Online) ; 36(4): 1461-1470, 01-06-2020. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1147322

RESUMO

This study aimed to determine the mechanical properties of fluoride-releasing dental materials after an accelerated fluoride recharge/discharge procedure. Two fluoride-releasing glass ionomer types of cement (Ketac Molar Easymix and IonoStar Molar), a resin-modified glass ionomer (Photac Fil Quick Aplicap), and two compomers (Compoglass F and Glasiosite) were used in this study. A total of 30 rectangular specimens and 30 disk specimens of each material were prepared and placed in distilled/deionized water (n = 5). The amount of fluoride released was analyzed from the materials for 7-day discharge, 1st recharge, 7-day discharge, 2nd recharge, and 7-day discharge, and 3rd recharge. The de/pre- and post-recharge fluoride release were measured using an ion chromatography for 24 days. The flexural strength and microhardness of each group were evaluated. The microhardness of all restorative materials showed no significant change (p > 0.05) over the experimental period. The flexural strength properties of the restorative materials did not change within the time of the study. The study showed that the fluoride release/uptake causes no effect on the mechanical and physical properties of dental materials.


Este estudo teve como objetivo determinar as propriedades mecânicas de materiais dentários liberadores de flúor após um procedimento acelerado de recarga/descarga de flúor. Dois tipos de cimento de ionômero de vidro liberador de flúor (Ketac Molar Easymix e IonoStar Molar), um ionômero de vidro modificado por resina (Photac Fil Quick Aplicap) e dois compômeros (Compoglass F e Glasiosite) foram utilizados neste estudo. Um total de 30 amostras retangulares e 30 amostras de disco de cada material foram preparadas e colocadas em água destilada/deionizada (n = 5). A quantidade de fluoreto liberado foi analisada a partir dos materiais para descarga em 7 dias, 1ª recarga, descarga em 7 dias, 2ª recarga e descarga em 7 dias e 3ª recarga. A liberação de fluoreto pré e pós-recarga foi medida usando uma cromatografia de íons por 24 dias. A resistência à flexão e a microdureza de cada grupo foram avaliadas. A microdureza de todos os materiais restauradores não apresentou alteração significativa (p > 0,05) durante o período experimental. As propriedades de resistência à flexão dos materiais restauradores não mudaram no período do estudo. O estudo mostrou que a liberação/captação de flúor não afeta as propriedades mecânicas e físicas dos materiais dentários.


Assuntos
Flúor , Cimentos de Ionômeros de Vidro
19.
Braz. dent. sci ; 23(3): 1-8, 2020. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1117327

RESUMO

Objective: This study aimed to evaluate the surface microhardness and morphology, as well as the microshear bond strength of a self-etching adhesive (Clearfil SE, Kuraray) to eroded dentin, exposed or not to cigarette smoke. Forty dental crowns were divided into 4 groups (n = 10): no treatment (control) (C); erosion (E); erosion + cigarette smoke exposure (ES); cigarette smoke exposure (S). Samples were prepared through third molars polishing until dentin exposure, followed by crown section. Erosive cycles were performed 5 times/day for 30 s at 60 min intervals. Cigarette smoke was produced with twenty cigarettes/day, during 5 days. Microhardness was evaluated initially and after the treatments. Microshear bond strength was tested after the treatments and dentin restoration with flow composite. Failure patterns and dentin morphology was evaluated by Scanning Electron Microscopy. Microshear bond strength data was submitted to two-way ANOVA, microharness test was adjusted by gamma distribution to be a non-parametric analyses (p=0.05), and surface morphology as qualitative analyses. Loss percentage of microhardness was observed only in groups submitted to erosion. Bond strength was statistically similar between all groups. The most prevalent failure pattern was of adhesive type. Morphological analysis of dentin showed obliterated tubules in groups submitted to cigarette smoke exposure. Cigarette smoke exposure did not promote any effect in the percentage of microhardness loss, as in sound dentin as in eroded dentin. Cigarette smoke, erosion, and association of both, did not alter the bond strength of self-etching adhesives to dentin. (AU)


Objetivo: Este estudo teve como objetivo avaliar a microdureza (% perda de dureza) e morfologia de superfície (MS), assim como a resistência de união (RU) de um adesivo autocondicionante (Clearfil SE, Kuraray) à uma dentina erodida, exposta ou não à fumaça de cigarro. Material e Métodos: Quarenta coroas dentais de terceiros molares foram seccionadas da raiz e polidas até a exposição dentinária, sendo aleatoriamente divididas em 4 grupos (n=10): sem tratamento (controle), erosão (E), erosão+ exposição a fumaça de cigarro (ES); exposição a fumaça de cigarro (S).O ciclo erosivo foi realizado 5 vezes/dia por 30s, com 60 minutos de intervalo entre eles. Os grupos ES e S foram exposto à fumaça de cigarro produzida por 20 cigarros/dia, durante 5 dias. A avaliação da microdureza foi realizada antes e após os tratamentos, enquanto a resistência da união por microcisalhamento foi realizada após os tratamentos Os padrões de fratura representativos e a MS dentinária foram avaliados por microscopia eletrônica de varredura (MEV). Os dados de RU foram analisados por ANOVA dois fatores, enquanto a análise de microdureza foi ajustada por distribuição gama por ser uma análise não-paramétrica (p=0.05). A MS foi analisada qualitativamente. Resultados: Os grupos expostos aos ciclos erosivos (E e ES) apresentaram % de perda de dureza significativamente menor que os grupos não expostos (Controle e S. aos ciclos erosivos (E e ES). Para RU, não houve diferença estatística significativa entre os grupos. O padrão de fratura mais observado foi do tipo adesivo, e através das imagens obtidas por MEV, observou-se a obliteração de túbulos dentinários no grupo exposto à fumaça de cigarro, enquanto os grupos submetidos aos ciclos erosivos (E e ES) apresentaram maior exposição e diâmetro de túbulos dentinários. Conclusão: A exposição à fumaça de cigarro não promove nenhum efeito quanto a perda de porcentagem de dureza dentinária, assim como em dentina erodida e saudável. A fumaça de cigarro, o processo erosivo, e a associação de ambos, não altera a resistência da união de adesivos autocondicionantes à dentina. (AU)


Assuntos
Resistência à Tração , Erosão Dentária , Coroas , Cimentos Dentários , Produtos do Tabaco
20.
Odovtos (En línea) ; 21(3): 101-110, Sep.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1091496

RESUMO

ABSTRACT The purpose of this study was to evaluate the effect of the use of the combined auxiliaries of oral hygiene with whitening agents on the micro-hardness and micro-morphology of dental enamel. Materials and Methods. 40 human incisors were used and sectioned to obtain 4x4mm samples and divided into four study groups. Group 1: Electric brushing with Toothpaste (BTP); Group 2: Electric brushing with Toothpaste+mouthwash (BTP+MW); Group 3: Electric brushing with Toothpaste+whitening pen (BTP+WP); Group 4: Electric brushing with Toothpaste+mouth wash+whitening pen (BTP+MW+WP). Samples were submitted toVickers micro-hardness test and visualized using scanning electron microscopy (SEM). Results. All groups, with the exception of group 1, showed a decrease in micro- hardness values after applying the treatments (p<0.05). Likewise, when comparing the values after the treatments between the groups, significant statistical differences were found in all of comparisons except for those of groups 2 and 4. SEM images showed changes in the morphology in all the study groups with the exception of group 1. Conclusion. Significant changes such as decrease in micro-hardness as well as in the topography of the enamel surface such as elevations, craters, porosities and etching patterns were founded after the use of the combination of auxiliaries of oral hygiene with whitening agents.


RESUMEN El propósito de este estudio fue evaluar el efecto del uso de los auxiliares de higiene oral combinados con agentes blanqueadores sobre la microdureza y la micro-morfología del esmalte dental. Materiales y métodos. Se utilizaron 40 incisivos humanos y se seccionaron para obtener muestras de 4x4 mm los cuales se dividieron en cuatro grupos de estudio. Grupo 1: cepillado eléctrico con pasta de dientes (BTP); Grupo 2: cepillado eléctrico con pasta dental+enjuague bucal (BTP+MW); Grupo 3: cepillado eléctrico con pasta dental+pluma blanqueadora (BTP+WP); Grupo 4: cepillado eléctrico con pasta dental+enjuague bucal+pluma blanqueadora (BTP+MW+WP). Las muestras fueron analizadas por medio de microdurezaVickers y microscopía electronica de barrido (SEM). Resultados. Todos los grupos, con la excepción del grupo 1, mostraron una disminución en los valores de microdureza después de aplicar los tratamientos (p<0.05). Del mismo modo, al comparar los valores después de los tratamientos entre los grupos, se encontraron diferencias estadísticamente significativas en todas las comparaciones, excepto en las de los grupos 2 y 4. Las imágenes de SEM nos muestran cambios en la morfología en todos los grupos de estudio con la excepción del grupo 1 Conclusión. Cambios significativos como la disminución de la microdureza y los cambios en la topografía de la superficie del esmalte, como elevaciones, cráteres, porosidades y patrones de grabado, se encontraron después del uso de la combinación de auxiliares de la higiene oral con agentes blanqueadores.


Assuntos
Humanos , Higiene Bucal , Microscopia Eletrônica de Varredura , Produtos para Higiene Dental e Bucal , Clareamento Dental/tendências , Escovação Dentária , Dispositivos para o Cuidado Bucal Domiciliar , Esmalte Dentário/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...